Data Centers
Equinix SV11 Data Center
Silicon Valley, CA
LOCATION
Silicon Valley, CA
COOLING CAPACITY
45 MW
STRAINERS INSTALLED
24 Units
COMPLETION
2024
The Equinix SV11 Data Center required a comprehensive fluid filtration solution to protect critical cooling infrastructure. With over 45 megawatts of IT load capacity, uninterrupted cooling is essential. Hellan Fluid Systems engineered a complete strainer package featuring our Online Cleanable Strainers that provide continuous 24/7 self-cleaning operation without system shutdown.
The installation includes 24 Model 850 Automatic Strainers strategically positioned throughout the cooling loop, protecting chillers, pumps, and heat exchangers from debris that could cause equipment failure or reduced efficiency. The self-cleaning mechanism activates automatically based on differential pressure, ensuring optimal flow rates at all times.
Additionally, custom-engineered Cooling Skids were delivered pre-assembled and tested, reducing on-site installation time by 60%. Each skid integrates strainers, pumps, valves, and instrumentation into a single plug-and-play unit, meeting the aggressive construction timeline without compromising quality.
PROJECT GALLERY

Central cooling plant featuring Hellan Online Cleanable Strainers for continuous operation
FILTRATION SYSTEMS INSTALLED
Online Cleanable Strainers
Self-cleaning strainers providing 24/7 continuous operation without system shutdown.
Cooling Skids
Pre-assembled, factory-tested cooling packages with integrated strainers and pumps.
Suction Diffusers
Combination strainer and flow straightener protecting pump suction.
TECHNICAL SPECIFICATIONS
Strainer Details
| Model | 850 Automatic |
| Quantity | 24 Units |
| Pipe Sizes | 8" - 16" |
| Body Material | Cast Iron / Ductile Iron |
| Basket Material | 316 Stainless Steel |
| Perforation Size | 1/16" (1.6mm) |
System Performance
| Total Flow Rate | 48,000 GPM |
| Operating Pressure | 150 PSI |
| Temperature Range | 40°F - 120°F |
| Clean Cycle Time | 15 seconds |
| Uptime | 99.999% |
| Certifications | ISO 9001, UL Listed |
"Hellan's Online Cleanable Strainers have been running continuously for over two years without a single unplanned shutdown. The self-cleaning technology has eliminated the maintenance windows we used to schedule, improving our overall uptime to 99.999%. For mission-critical data center cooling, there's simply no better solution."
TECHNICAL DOCUMENTATION
Specifications
Ready to Discuss Your Project?
Our engineering team can help you select the right filtration solution for your data center cooling infrastructure.